problems with WRT54G v5 vxworks upgrade

Discussion in 'DD-WRT Firmware' started by robr, Aug 8, 2006.

  1. robr

    robr Network Guru Member

    Greetings, I'm following the wiki here
    http://www.bitsum.com/openwiking/owbase/ow.asp?WRT54G5_CFE

    to flash my WRT54G V5

    After the step that says to flash with vxworks_prep_v03.bin file, my browser "went blank" (actually said it couldn't connect) so I rebooted.

    The next step says to connect to the router again, but I can't ping it and the power light is flashing (it mentions that the power light will do this after the next step, but I can't get that far).

    I'm wondering what I can do at this point and why this might have happened (I'm almost positive I did not flash the wrong file in step 1, I double checked before clicking the icon, but I suppose anything is possible).
     
  2. speeddemon

    speeddemon LI Guru Member

    Oke i know the problem i have to a wrt54g v5 the 1st thing you must do is give you networkcard a static IP 192.168.1.10 and a static gateway : 192.168.1.1 this wil do it when you did this you can connect again and you wil get a manager so you can uploud the file use the rest of the wiki manual
     